Pre-order

HibouAir Duo Extended CO + O₂

Carbon monoxide and oxygen. One connected view.

Bring carbon monoxide and oxygen measurements together with the standard Duo Extended indoor air sensors. Follow gas, CO₂, particle, temperature and humidity trends through a compact BLE monitor.

SSD002/4B-1
CO + O₂Dual gas configuration
White square Duo Extended enclosure with a plain front and ventilation slots, illustrated from the supplied datasheet
More in every measurement CO + O₂ CO₂ PM1.0 / 2.5 / 10 Temperature Humidity

Made for a clearer view

The gas you need.
The context that matters.

Dedicated additional gas sensing meets laser-scattering particulate measurement and NDIR CO₂ technology. Follow individual readings and the indoor conditions around them.

Carbon monoxide (CO)0–100 ppm

0.1 ppm resolution

Additional gas sensor
Oxygen (O₂)0–25% vol.

0.01% vol. resolution

Additional gas sensor
Indoor air essentialsCO₂ + PM

Plus temperature and humidity

Included in every variant
Built-in data loggerYour history

Save readings at your preferred interval

Days, weeks or months of data

Explore an application

A building-performance laboratory, in context

Explore an indoor research setting where carbon monoxide and oxygen measurements form part of a wider environmental record. Select a numbered point to explore.

Two building-performance researchers review a closed ventilation test bench in a bright laboratory, with a white HibouAir-style monitor on the foreground bench.
01

CO and oxygen, side by side

The CO channel spans 0–100 ppm at 0.1 ppm resolution. The O₂ channel spans 0–25% by volume at 0.01% by volume resolution.

02

The whole indoor picture

Every variant also includes CO₂, PM1.0, PM2.5, PM10, temperature and humidity. Review these measurements together to give your gas observations more context.

03

A record you can revisit

A built-in data logger offers storage intervals programmable in one-minute steps. Access historical data and generate PDF reports for analysis and sharing.

Explore the measurements
02

Building-performance research

Include both carbon monoxide and oxygen in an indoor monitoring study.

03

Facilities measurement projects

Review gas readings alongside particles and the standard CO₂ channel.

04

Project reporting

Use stored measurements and historical PDF reports to share observations with a team.

Built-in data logger

Capture now.
Understand over time.

Move beyond a single reading. Set the storage interval to suit your project, revisit historical measurements, and turn observations into PDF reports.

Read the datasheet
  1. 01

    Choose your interval

    Programmable storage intervals in one-minute steps.

  2. 02

    Build your history

    Store measurements for days, weeks or months, depending on your preferred interval.

  3. 03

    Share the observations

    Access historical data and generate PDF reports for analysis and documentation.

Your monitor. Your setup.

Choose how you use it.

HibouAir Duo Extended CO + O₂
SSD002/4B-1 · Carbon monoxide + oxygen

Choose a solution
Device subtotal$260.00Shipping, applicable tax and setup extras excluded.
Add to cart

Send your selected model and quantity to our team to arrange your purchase.

Know your monitor

Specifications, in detail.

SSD002/4B-1
Technical specifications from the SSD002/4B datasheet, version 2.0.

Additional gas sensors

Additional gas ranges and resolution for SSD002/4B-1
Measurement Range Resolution
Carbon monoxide (CO) 0–100 ppm 0.1 ppm
Oxygen (O₂) 0–25% vol. 0.01% vol.

Additional gas sensing uses solid polymer electrochemical technology. Gas accuracy is not specified in this datasheet; resolution is shown separately above.

Core sensors included in every variant

Core sensor ranges and accuracy
Measurement Range Accuracy
CO₂ 400–10,000 ppm ± (30 ppm / 3%)
PM1.0 / PM2.5 / PM10 0–1,000 µg/m³ ±5 µg/m³ at 0–35 µg/m³; ±10% at 35–1,000 µg/m³
Temperature −5 to +65°C ±0.5°C
Relative humidity 0–100% r.H. ±4% r.H.

CO₂ accuracy notation is reproduced as supplied in the datasheet. Sensor measurement ranges and device working conditions are listed separately.

Device specifications

Connectivity
Bluetooth Low Energy 5.2
Power
+5 VDC input on micro USB connector
Dimensions
88 × 88 × 33 mm
Weight
250 g
Working conditions
−20°C to +65°C; humidity: 100% (as listed in the datasheet)
Certification / compliance
CE, RoHS, REACH
Colour
White

A few useful details

Before you choose.

Talk to the HibouAir team
What does this variant measure?

HibouAir Duo Extended CO + O₂ (SSD002/4B-1) includes carbon monoxide + oxygen monitoring, plus CO₂, PM1.0, PM2.5, PM10, temperature and humidity. Each Duo Extended variant has its own additional gas configuration.

Does the device connect directly to Wi-Fi?

This model uses Bluetooth Low Energy 5.2. For a computer or Cloud Enterprise deployment, discuss the required USB dongle or BLE gateway and application support with our team.

How is it powered?

The datasheet specifies a +5 VDC input through a micro USB connector. The enclosure measures 88 × 88 × 33 mm and weighs 250 g.

How long can it log measurements?

You can set the logging interval in one-minute steps to suit your monitoring needs. Depending on your preferred interval, the built-in data logger can store measurements for days, weeks or months. Choose a shorter interval for a more detailed record, or a longer interval to keep a history over a longer period.

What is included in the displayed price?

The displayed amount is the price of the selected device and quantity. Shipping, applicable tax, USB dongles, gateways and cloud plans are additional. Enquire with your preferred setup for a complete purchase quotation.